Przeglądanie stron 13
BENDIX/KING
KAP 140
Page 1--8
Revision 6, Oct 2002
CS:00991I06.IDU
KS 270/1/2 C
TSO Compliance: See Appendix A
Physical Dimensions(Nominal):
Length: 4.605 in (11.70 cm) without
KM275 or KM277
Height: 4.675 in (11.87 cm)
Width: 3.925 in (9.97 cm)
Weight: (Nominal)
KS 270C: 2.5 lbs (1.09 kg)
KS 271C: 2.2 lbs (1.00 kg)
KS 272C: 2.1 lbs (0.95 kg)
KM 275 Servo Mount 1.0lbs (.45 Kg)
KM 277 Servo Mount
Mounting: Two (2) AN 3 bolts
Mating Connector: 030--03248--0000
Power Inputs: +28VDC at 4.0 amps
Signal Inputs:
Servo Drive Command: --10VDC to +10VDC
Clutch Engage Signals: +28VDC(Active high input)
and Ground(Active low input)
Signal Outputs:
Trim Voltage --28VDC to +28VDC
Trim Sense --3VDC to +3VDC